BusLogic MultiMaster and FlashPoint SCSI Driver for Linux — The Linux Kernel documentation

The Linux Kernel 7.4.0-rc3 Quick search Contents Working with the development community Development process Submitting patches Code of conduct Maintainer handbook All development-process docs Internal API manuals Core API Driver APIs Subsystems Core subsystems Human interfaces Networking interfaces Storage interfaces Filesystems in the Linux kernel Block CD-ROM SCSI Subsystem TCM Virtual Device NVMe Subsystem Other subsystems Locking Development tools and processes Licensing rules Writing documentation Development tools Testing guide Hacking guide Tracing Fault injection Livepatching Rust User-oriented documentation Administration Build system Reporting issues Userspace tools Userspace API Firmware-related documentation Firmware Firmware and Devicetree Architecture-specific documentation CPU architectures Other documentation Unsorted documentation Translations Translations This Page Show Source BusLogic MultiMaster and FlashPoint SCSI Driver for Linux ¶ Version 2.0.15 for Linux 2.0 Version 2.1.15 for Linux 2.1 PRODUCTION RELEASE 17 August 1998 Leonard N.

Zubkoff Dandelion Digital lnz @ dandelion . com Copyright 1995-1998 by Leonard N. Zubkoff < lnz @ dandelion . com > Introduction ¶ BusLogic, Inc. designed and manufactured a variety of high performance SCSI host adapters which share a common programming interface across a diverse collection of bus architectures by virtue of their MultiMaster ASIC technology. BusLogic was acquired by Mylex Corporation in February 1996, but the products supported by this driver originated under the BusLogic name and so that name is retained in the source code and documentation.

This driver supports all present BusLogic MultiMaster Host Adapters, and should support any future MultiMaster designs with little or no modification. More recently, BusLogic introduced the FlashPoint Host Adapters, which are less costly and rely on the host CPU, rather than including an onboard processor. Despite not having an onboard CPU, the FlashPoint Host Adapters perform very well and have very low command latency.

BusLogic has recently provided me with the FlashPoint Driver Developer’s Kit, which comprises documentation and freely redistributable source code for the FlashPoint SCCB Manager. The SCCB Manager is the library of code that runs on the host CPU and performs functions analogous to the firmware on the MultiMaster Host Adapters. Thanks to their having provided the SCCB Manager, this driver now supports the FlashPoint Host Adapters as well.

My primary goals in writing this completely new BusLogic driver for Linux are to achieve the full performance that BusLogic SCSI Host Adapters and modern SCSI peripherals are capable of, and to provide a highly robust driver that can be depended upon for high performance mission critical applications. All of the major performance features can be configured from the Linux kernel command line or at module initialization time, allowing individual installations to tune driver performance and error recovery to their particular needs.

The latest information on Linux support for BusLogic SCSI Host Adapters, as well as the most recent release of this driver and the latest firmware for the BT-948/958/958D, will always be available from my Linux Home Page at URL “ http://sourceforge.net/projects/dandelion/ ”. Bug reports should be sent via electronic mail to “ lnz @ dandelion . com ”. Please include with the bug report the complete configuration messages reported by the driver and SCSI subsystem at startup, along with any subsequent system messages relevant to SCSI operations, and a detailed description of your system’s hardware configuration.

Mylex has been an excellent company to work with and I highly recommend their products to the Linux community. In November 1995, I was offered the opportunity to become a beta test site for their latest MultiMaster product, the BT-948 PCI Ultra SCSI Host Adapter, and then again for the BT-958 PCI Wide Ultra SCSI Host Adapter in January 1996. This was mutually beneficial since Mylex received a degree and kind of testing that their own testing group cannot readily achieve, and the Linux community has available high performance host adapters that have been well tested with Linux even before being brought to market.

This relationship has also given me the opportunity to interact directly with their technical staff, to understand more about the internal workings of their products, and in turn to educate them about the needs and potential of the Linux community. More recently, Mylex has reaffirmed the company’s interest in supporting the Linux community, and I am now working on a Linux driver for the DAC960 PCI RAID Controllers. Mylex’s interest and support is greatly appreciated.

Unlike some other vendors, if you contact Mylex Technical Support with a problem and are running Linux, they will not tell you that your use of their products is unsupported. Their latest product marketing literature even states “Mylex SCSI host adapters are compatible with all major operating systems including: ... Linux ...”. Mylex Corporation is located at 34551 Ardenwood Blvd., Fremont, California 94555, USA and can be reached at 510/796-6100 or on the World Wide Web at http://www.mylex.com .

Mylex HBA Technical Support can be reached by electronic mail at techsup @ mylex . com , by Voice at 510/608-2400, or by FAX at 510/745-7715. Contact information for offices in Europe and Japan is available on the Web site. Driver Features ¶ Configuration Reporting and Testing ¶ During system initialization, the driver reports extensively on the host adapter hardware configuration, including the synchronous transfer parameters requested and negotiated with each target device.

AutoSCSI settings for Synchronous Negotiation, Wide Negotiation, and Disconnect/Reconnect are reported for each target device, as well as the status of Tagged Queuing. If the same setting is in effect for all target devices, then a single word or phrase is used; otherwise, a letter is provided for each target device to indicate the individual status. The following examples should clarify this reporting format: Synchronous Negotiation: Ultra Synchronous negotiation is enabled for all target devices and the host adapter will attempt to negotiate for 20.0 mega-transfers/second.

Synchronous Negotiation: Fast Synchronous negotiation is enabled for all target devices and the host adapter will attempt to negotiate for 10.0 mega-transfers/second. Synchronous Negotiation: Slow Synchronous negotiation is enabled for all target devices and the host adapter will attempt to negotiate for 5.0 mega-transfers/second. Synchronous Negotiation: Disabled Synchronous negotiation is disabled and all target devices are limited to asynchronous operation.

Synchronous Negotiation: UFSNUUU#UUUUUUUU Synchronous negotiation to Ultra speed is enabled for target devices 0 and 4 through 15, to Fast speed for target device 1, to Slow speed for target device 2, and is not permitted to target device 3. The host adapter’s SCSI ID is represented by the “#”. The status of Wide Negotiation, Disconnect/Reconnect, and Tagged Queuing are reported as “Enabled”, Disabled”, or a sequence of “Y” and “N” letters.

Performance Features ¶ BusLogic SCSI Host Adapters directly implement SCSI-2 Tagged Queuing, and so support has been included in the driver to utilize tagged queuing with any target devices that report having the tagged queuing capability. Tagged queuing allows for multiple outstanding commands to be issued to each target device or logical unit, and can improve I/O performance substantially. In addition, BusLogic’s Strict Round Robin Mode is used to optimize host adapter performance, and scatter/gather I/O can support as many segments as can be effectively utilized by the Linux I/O subsystem.

Control over the use of tagged queuing for each target device as well as individual selection of the tagged queue depth is availab